Applications:
Melting and roasting furnaces, drying drums, reactors, furnaces, etc.
Main advantages:
High purification efficiency, low aerodynamic resistance. B ECOFILTER сhemical resistance: to acids (except hydrofluoric acid), saline solutions and organic solvents.
Parameter | Measurement unit | Value |
Filtration rating. | μm | ≤ 0.3 |
Substrate porosity. | % | 90 |
Material density. | g/cm 2 | 0.4 |
Flexural strength (annular compression). | MPa | ≥ 1 |
Maximum temperature stability. | °C | 1000 |
Filtration of hot gases in an oxidizing medium. | °C | 750 |
Filtration of hot gases in a reducing medium. | °C | 600 |
Filtration rate. | m/min | up to 3 |
Table of dimensions of ceramic filter elements
Length, mm | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Number of sections | 1 | 1 | 1 or 2 | 2 | 2 | 3 |
Outer/inner diameter, mm | 60/40 150/110 | 150/110 | ||||
Type of flange | T | T/V | T/V | T/V | T/V | V |
Filtration area, m2 | 0.18 / 0.47 | 0.36 / 0.94 | 1.41 | 1.89 | 2.35 | 2.83 |
Weight, kg. | 0.8 / 2 | 1.6 / 4 | 6 | 8 | 10 | 12 |
Веб-форма не найдена.